Dominant Aerosol Chemical Components and Their Contribution to Extinction During the Aerosols99 Cruise Across the Atlantic



Download 324.84 Kb.
Page1/5
Date29.01.2017
Size324.84 Kb.
#12629
  1   2   3   4   5


Dominant Aerosol Chemical Components and Their Contribution to Extinction During the Aerosols99 Cruise Across the Atlantic

P.K. Quinn, D.J. Coffman, T.S. Bates, T.L. Miller, J.E. Johnson

Pacific Marine Environmental Laboratory, NOAA, Seattle, Washington

Joint Institute for the Study of the Atmosphere and Ocean, University of Washington, Seattle


K. Voss

University of Miami, Miami, FL


E.J. Welton

Goddard Space Flight Center, NASA, Greenbelt, Maryland


C. Neusüss

Institute for Tropospheric Research, Leipzig, Germany


For submission to the Journal of Geophysical Research June 22, 2000



Abstract. The Aerosols99 cruise crossed the Atlantic Ocean from Norfolk, Virginia to Cape Town, South Africa during January and February of 1999. Based on back trajectories, aerosol number concentrations and size distributions, and trace gas concentrations, seven “air mass” regions were encountered. These included North America, northern hemisphere (NH) marine, African dust, a mixture of dust and biomass burning from Africa, biomass burning from Africa, southern hemisphere (SH) marine tropics, and SH marine temperate. Simultaneous measurements of aerosol chemical composition, number size distribution, scattering and absorption coefficients, vertical profiles, and optical depth allowed for a thorough characterization of the aerosol. Presented here are the concentrations and mass fractions of the aerosol chemical components that were dominant in each region and the aerosol scattering and absorption coefficients, single scattering albedos, Ångström exponents, and optical depths measured in each region. Also presented is the percent of the extinction measured at the surface due to each chemical component and mass extinction efficiencies of the individual aerosol components estimated from Mie calculations and a multiple linear regression. All results are reported at the measurement relative humidity of 55  5%. Non sea salt (nss) SO4= aerosol was a significant contributor to the submicron mass concentration in all air mass regions (mean mass fractions ranged from 20 to 67%). It made the largest contribution to submicron extinction in the North America region (25 22%, mean and 1 standard deviation). Sea salt mean submicron mass fractions ranged from 9 to 49% with the lowest value in the biomass burning region and highest values in the NH marine and dust regions. Its contribution to submicron extinction ranged from a mean of 29 to 69%. Sea salt mean supermicron mass fractions ranged from 52 to 98% with the highest values in the marine regions. Its contribution to supermicron extinction ranged from 71 to 98%. Mean submicron and supermicron mass fractions of dust in the dust region were 22  3.3% (mean and 95% uncertainty) and 26  3.9%, respectively. Corresponding sub- and supermicron extinction contributions were 23  7.7 and 15  3.5%, respectively. Submicron mass fractions of particulate organic matter (POM) ranged from below detection limits in the dust region to 18  11% in the biomass burning region. Contributions to submicron extinction ranged from below detection limits to 31% in the North America region. In the biomass burning region, the black carbon mean submicron mass fraction was 6.7  1.3% with a contribution of 14  0.1% to the submicron extinction. Extinction fractions of each component for particles with aerodynamic diameters less than 10 m also are reported in the paper. The fraction of the measured column aerosol optical depth due to aerosol within the boundary layer was estimated for the NH marine, dust, biomass burning, and SH marine tropics regions. Mean values ranged from 35  15% for the biomass burning region to 95  46% for the NH marine region.

1. Introduction

It is well known that radiative forcing by tropospheric aerosols is one of the largest uncertainties in model calculations of climate forcing [IPCC, 1996]. This is due, in large part, to regionally varying aerosol sources, concentrations, and compositions and the difficulty of making the required in situ measurements of relevant aerosol properties on a global scale. One approach for characterizing aerosol properties over large geographical regions is shipboard cruises with aerosol instrumentation capable of characterizing both surface and column properties (in situ instrumentation for the measurement of aerosol chemical, physical, and optical properties; a sunphotometer for the measurement of aerosol optical depth; and a lidar for the measurement of aerosol vertical profiles). The Aerosols99 cruise was a diagonal transect across the Atlantic Ocean leaving Norfolk, Virginia on January 14, 1999 and arriving in Cape Town, South Africa on February 8, 1999. A goal of the cruise was to characterize the aerosol over regions of the Atlantic Ocean known to be impacted by continental emissions and over regions thought to be relatively pristine. In situ measurements of aerosol chemical composition and light scattering and absorption coupled with air mass back trajectories confirm that a wide range of aerosol types were encountered. These included aerosol from eastern North America, dust and biomass burning aerosol from Africa, and marine aerosol from the North and South Atlantic.

Based on back trajectories, aerosol number concentrations and size distributions, and trace gas concentrations, samples collected along the cruise track were divided into seven regions that reflect the recent history of the sampled air masses. These “air mass” regions and their latitude bounds are North America (37 to 31N), northern hemisphere (NH) marine (31 to 15.5N), African dust (15.5 to 8N), mixture of African dust and biomass burning (8 to 3N), African biomass burning (3N to 5S), southern hemisphere (SH) marine tropics (5 to 24.5S), and SH marine temperate (24.5 to 33S). The meteorology resulting in these distinct regions and the chemical and physical properties of the aerosol along the cruise track are described in an overview paper in this issue [Bates et al., 2000].

Presented here are the concentrations and mass fractions of the chemical components (defined as the component concentration divided by total aerosol mass concentration), the percent of measured extinction due to each component, and mass extinction efficiencies of the chemical components for different regions. The chemical components considered include non-sea salt (nss) sulfate aerosol, sea salt, particulate organic matter (POM), black carbon (BC), and dust. Also presented for the regions are average aerosol scattering and absorption coefficients, the backscattered fraction, aerosol optical depth, and the portion of the aerosol optical depth due to boundary layer aerosol.

The derivation of the percent of extinction due to each component and the mass extinction efficiencies requires Mie calculations that use the measured chemical composition and number size distributions as input. To test for consistency in the input data and to assess the accuracy of the Mie calculations, closure tests were performed between measured and calculated parameters. These parameters include aerosol mass (measured gravimetrically, derived from chemical analysis, and estimated from the number size distribution) and aerosol light extinction and single scattering albedo (derived from measured light scattering and absorption coefficients and calculated from Mie theory). In addition, mass extinction efficiencies were calculated with two independent methods (Mie calculations and a multiple linear regression). Results of these comparisons are presented. A more detailed discussion of mass closure for the Aerosols99 cruise can be found in Lienert et al. [2000].


  1. Measurements

2.1. Aerosol sample inlet

Sample air for the chemical and optical measurements was drawn through a 6-m sample mast. The entrance to the mast was 18 m above sea level and forward of the ship’s stack. To maintain nominally isokinetic flow and minimize the loss of supermicron particles, the inlet was rotated into the relative wind. Air entered the inlet through a 5-cm diameter hole, passed through an expansion cone, and then into the 20-cm diameter sampling mast. The flow through the mast was 1 m3 min-1. The last 1.5 m of the mast were heated to establish a stable reference relative humidity (RH) for the sample air of 55  5%. This allows for constant instrumental size segregation in spite of variations in ambient RH. All results are reported at 55% RH. Individual 1.9 cm diameter stainless steel tubes extended into the heated portion of the mast. These were connected to the aerosol instrumentation and impactors with graphite-polyethylene conductive tubing to prevent the electrostatic loss of particles. An exception to this was the lines connected to the impactors used for collection of carbonaceous aerosol; they were constructed of stainless steel. Air was sampled only when the concentration of particles greater than 15 nm in diameter indicated the sample air was free of contamination, the relative wind speed was greater than 3 m s-1, and the relative wind was forward of the beam.



2.2. Regional concentrations of inorganic ions

Two-stage multi-jet cascade impactors (Berner et al., 1979) sampling air at 55  5% RH were used to determine the sub- and supermicron concentrations of Cl-, NO3-, SO4=, methanesulfonate (MSA-), Na+, NH4+, K+, Mg+2, and Ca+2. The RH of the sampled air stream was measured a few inches upstream from the impactor. The 50% aerodynamic cutoff diameters, D50,aero, were 1.1 and 10 m. Throughout the paper submicron refers to particles with Daero < 1.1 m at 55% RH and supermicron refers to particles with 1.1 m < Daero < 10 m at 55% RH.

The impaction stage at the inlet of the impactor was coated with silicone grease to prevent the bounce of larger particles onto the downstream stages. Tedlar films were used as the collection substrate in the impaction stage and a Millipore Fluoropore filter (1.0-m pore size) was used for the backup filter. Films were cleaned in an ultrasonic bath in 10% H2O2 for 30 min, rinsed in distilled, deionized water, and dried in an NH3- and SO2-free glove box. Filters and films were wetted with 1 mL of spectral grade methanol. An additional 5 mLs of distilled deionized water were added to the solution and the substrates were extracted by sonicating for 30 min. The extracts were analyzed by ion chromatography [Quinn et al., 1998]. All handling of the substrates was done in the glove box. Blank levels were determined by loading an impactor with substrates but not drawing any air through it.

Non-sea salt sulfate concentrations were calculated from Na+ concentrations and the ratio of sulfate to sodium in seawater. Sea salt aerosol concentrations were calculated as

sea salt (g m-3) = Cl- (g m-3) + Na+ (g m-3) x 1.47 (1)

where 1.47 is the seawater ratio of (Na+ + K+ + Mg+2 + Ca+2 + SO4= + HCO3-) / Na+ (Holland, 1978). This approach prevents the inclusion of non-seasalt K+, Mg+2, Ca+2, SO4=, and HCO3- in the sea salt mass and allows for the loss of Cl- mass through Cl- depletion processes. It also assumes that all measured Na+ and Cl- is derived from seawater. Results of Savoie and Prospero [1980] indicate that dust has a minimal contribution to measured soluble sodium concentrations.

Uncertainties of the ionic chemical components at the 95% confidence level are given in Tables 1 and 2. Uncertainties were propagated as a quadratic sum of all errors involved which assumes that all errors were random. Details of the uncertainty analysis can be found in Quinn et al. [2000].

2.3. Regional concentrations of total organic and black carbon

Three-stage multi-jet cascade impactors [Berner et al., 1979] sampling air at 55  5% RH were used to determine submicron and supermicron concentrations of total, organic, and black carbon. The impactor had D50,aero of 0.18, 1.1 and 10 m. Only in this case does submicron refer to 0.18 < Daero < 1.1 m. The 0.18 m jet plate was used instead of a quartz back-up filter to minimize positive artifacts due to the absorption of gas phase organics. Al foils, used as sampling substrates, were heated at the Institute for Tropospheric Chemistry (Leipzig, Germany) before the cruise at 600C for 4 hours to remove organic contaminants. Blank levels were determined by placing substrates into a second impactor and deploying the impactor for the duration of the sampling period without drawing air through it. Foils were stored frozen until analysis.

The samples were analyzed by a thermographic method using a commercial instrument (C-mat 5500, Ströhlein) [Neusüss et al., 2000]. The sample is placed in a quartz tube and heated rapidly to a specific temperature. To separate organic carbon (OC) and BC, the sample is first heated to 590C under nitrogen. The carbon compounds that evaporate under these conditions are referred to as OC. Then the sample is heated under oxygen to 650C and all carbon except carbonate is oxidized. The evaporated carbon is completely oxidized to CO2 followed by analysis with an IR detector. External standards are used to calibrate the measurements. As with all thermal carbon measurements, the OC/BC split is a method dependent property.

The mass of POM was determined by multiplying the measured organic carbon concentration in g C m-3 by a POM factor which is an estimated average of the molecular weight per carbon weight for the organic aerosol. Based on a review of published measurements of the composition of organic aerosol in urban and non-urban regions, Turpin and Lim [2000] found that values of 1.6  0.2 and 2.1  0.2 most accurately represent urban and non-urban aerosols, respectively. A value of 1.6 was used for the North American air masses and a value of 2.1 was used for all other air mass regions. The POM factor was assigned an absolute uncertainty of 0.35.

The uncertainties associated with positive and negative sampling artifacts can be substantial [Turpin et al., 1994; Turpin et al., 2000]. An effort was made to minimize positive artifacts by collecting samples on impaction plates. Negative artifacts may have occurred as a result of the pressure drop across the impactor (9 mb for the 1.1 m jet plate and 530 mb for the 0.18 m jet plate). No attempt was made to correct for artifacts or to determine their associated uncertainties since the information to do so was not available.

Uncertainties of the POM and BC concentrations at the 95% confidence level are reported in Tables 1 and 2. The uncertainties for BC are based on 2 times the standard deviation of the blank values measured over the course of the experiment. The uncertainties for POM are based on a quadrature sum of the uncertainty in the OC to POM conversion factor and 2 times the standard deviation of the blank over the course of the experiment.



2.4. Regional concentrations of dust and trace elements

Total elemental composition (Na, Mg, Al, Si, P, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ba, As, and Pb) was determined by thin-film x-ray primary and secondary –emission spectrometry [Feely et al., 1991; Feely et al., 1998]. Submicron samples were collected on Nuclepore filters (0.4 m pore size) mounted in a Berner impactor downstream of the D50,aero 1.1 m jet plate. Bulk samples were collected on Nuclepore filters (0.4 m pore size) in a filter pack having an upper D50,aero of 10 m. Supermicron elemental concentrations were determined by difference between the submicron and bulk samples. This method of sample collection allows for the sharp size cut of the impactor while collecting a thin film of aerosol necessary for the x-ray analysis.

Filters were acid washed before sample collection by soaking in 4 N HNO3 for 24 hrs and then 2% HCL for 24 hrs with multiple rinses with distilled deionized water between treatments. Filters were weighed before and after sample collection as described below. Blank levels were determined by loading an impactor or filter pack with a filter but not drawing any air through it.

For the regions of African dust and the dust/biomass burning mixture, dust concentrations were calculated from the Al mass concentration and an assumed dust to Al mass ratio of 12.5. This is based on the relatively constant 8% mass fraction of Al found in continental soils including Saharan dust [D. Savoie, pers. commun.]. An uncertainty of  20% was attached to the factor of 12.5. Outside of these regions, the concentrations of all elements measured by XRF were summed to create a “trace element” component mass concentration. Since the molecular form of the elements was not determined, the summed concentrations do not include any associated mass (e.g., the oxygen associated with aluminum oxide). This does not have a large effect on the overall mass closure, however, as the trace elements were a minor component of the mass (0.05 to 9% for the submicron mass and 0.2 to 1.9% for the supermicron mass) outside of the dust-containing regions. If the dominant elements in most regions (Al, Si, and Fe) were in their oxide form, the mass would have been underestimated by about 75%. Hence, an error of 75% was included in the uncertainty calculations.

Uncertainties at the 95% confidence level associated with the major elemental species (Al, Si, and Fe) are reported in Tables 1 and 2. Uncertainties were propagated as a quadratic sum of all errors involved including those due to the x-ray analysis, blank approximation, and volume of air sampled. XRF analysis errors are based on 2 times the standard deviation of 15 replicate analyses of a sample filter. Blank errors are based on 2 times the standard deviation of the average of all blanks collected over the course of the experiment.

2.5. Regional mass fractions

Sub- and supermicron regional mass fractions were calculated from concentrations of the measured chemical components and the XRF Nuclepore filters that were weighed before and after sample collection. The filters were weighed at PMEL with a Cahn Model 29 microbalance housed in a glove box kept at a humidity of 33  2%. The resulting mass concentrations from the gravimetric analysis include the water mass that is associated with the aerosol at 33% RH. Additional water mass may also be present due to interactions between the collected aerosol and the sampling substrate. The response of particles collected on a filter to changes in RH has been shown to be different than that of individual particles or bulk solutions of similar chemical composition [McInnes et al., 1996].

The glove box was continually purged with room air that had passed through a scrubber of activated charcoal, potassium carbonate, and citric acid to remove gas phase organics, acids, and ammonia. Static charging, which can result in balance instabilities, was minimized by coating the walls of the glove box with a static dissipative polymer (Tech Spray, Inc.), placing an anti-static mat on the glove box floor, using anti-static gloves while handling the substrates, and exposing the substrates to a 210Po source to dissipate any charge that had built up on the substrates. Before and after sample collection, substrates were stored double-bagged with the outer bag containing citric acid to prevent absorption of gas phase ammonia. More details of the weighing procedure can be found in Quinn and Coffman [1998].

Uncertainties of the mass fractions at the 95% confidence level are shown in Figures 3 and 4 and are based on a quadratic sum of the uncertainties of the chemical concentrations and the gravimetrically-determined mass. Uncertainty in the latter includes errors due to weighing, storage and transport, and the volume of air sampled Quinn et al. [2000]. To maintain the sampling RH of 55% the sample air was heated, on average, 5.4C (range of heating was 2 to 10C). This heating may have led to the volatilization of a portion of the semivolatile organics and ammonium nitrate from the substrate [Ayers et al., 1999] thereby resulting in artificially low masses. No attempt was made to correct for the artifact, however, as the composition of the semivolatile organics was unknown.



2.6. Aerosol scattering, backscattering, and absorption coefficients.

Measurements of aerosol scattering and hemispheric backscattering coefficients were made with an integrating nephelometer (Model 3563, TSI Inc.) at wavelengths of 450, 550, and 700 nm at 55% RH. The RH was measured inside the nephelometer sensing volume. A single-stage impactor with a D50,aero of 10 m was placed upstream of the nephelometer. Values measured directly by the nephelometer were corrected for an offset determined by measuring filtered air over a period of several hours [Anderson and Ogren, 1998]. In addition, they were corrected for the angular non-idealities (including truncation errors and nonlambertian response) of the nephelometer using



(2)

where sp_True is the “true” scattering coefficient determined from the measured number size distribution and chemistry and a Mie scattering model and sp_Neph_sim is the nephelometer simulated scattering coefficient determined from Mie scattering model which employs a Mie integral modified to simulate the nephelometer response [Quinn and Coffman, 1998]. (The Mie calculations are discussed in more detail below.) This correction is similar to that of Anderson and Ogren [1998] but uses the simultaneously measured size distribution rather than an assumed size distribution. Values are reported at 0C and 1013 mb.

Sources of uncertainties associated with the use of the integrating nephelometer include photon counting during measurement, zeroing, and calibration; literature values of calibration gas scattering coefficients; variations in gas density within the nephelometer, and the angular correction applied in equation (2). These uncertainties were estimated using the method of Anderson et al., [1999]. Additional uncertainties include variations in measured scattering due to RH changes within the nephelometer sensing volume and inlet losses of large particles [Quinn and Coffman, 1998]. For a 30 minute averaging time, a quadrature sum of errors yielded absolute uncertainties of 4.1 and 20 Mm-1 corresponding to low and high values of sp equal to 24 and 110 Mm-1, respectively. Absolute uncertainties for bsp equal to 3.0 and 13 Mm-1 were 0.32 and 1.3 Mm-1, respectively.

The absorption coefficient for sub-10m aerosol, ap, was measured at 565 nm and 55% RH by monitoring the change in transmission through a filter with a Particle Soot Absorption Photometer (PSAP, Radiance Research). Measured values were corrected for a scattering artifact, the deposit spot size, the PSAP flow rate, and the manufacturer’s calibration as per Bond et al. [1999]. Values are reported at 0C and 1013 mb. Sources of uncertainty in the PSAP measurement include noise, drift, correction for the manufacturer's’calibration and correction for the scattering artifact [Anderson et al., 1999]. A quadrature sum of these errors yields absolute uncertainties of 0.38 and 2.8 Mm-1 for ap equal to 0.68 and 13 Mm-1, respectively, for a 30 minute averaging time.




Download 324.84 Kb.

Share with your friends:
  1   2   3   4   5




The database is protected by copyright ©ua.originaldll.com 2024
send message

    Main page